The Automatic Wire Stripping Machine is designed to evaluate the insulation strength and stripping performance of automotive wires. You can use this equipment to test the mechanical force required to remove insulation from conductors, ensuring consistent quality and compliance in automotive wire production.
Application
This machine is suitable for:
(1) Stripping force testing of automotive wires and cables.
(2) Evaluation of insulation bonding strength.
(3) Quality control in wire and cable manufacturing processes.
(4) Performance verification of automotive electrical wiring systems.
Standards
(1) SAE J1128-2005 – Low-voltage primary cable for automotive use
Parameters
| Parameter | Specification |
|---|---|
| Application Force Range | 12–20 kg, 1–200 kg |
| Acceleration Speed | 2.3 kg/min |
| Speed Adjustment Mode | Potentiometer / Computer software control |
| Steel Rod Diameter | 3 mm |
| Test Voltage | 24 V |
| Detection Current | 5 mA |
| Motor Type | Standard motor / Servo motor |
| Power | 500 W |
| Power Supply | 220 V |
Features
(1) Wide Force Range – Supports testing from low to high stripping force requirements.
(2) Flexible Speed Control – Adjustable via potentiometer or software for precise operation.
(3) Automated Reporting – Generates test data reports for quality tracking and documentation.
(4) Stable Drive System – Optional servo motor ensures accurate and repeatable test performance.
(5) Reliable Detection System – Low current detection improves test sensitivity and safety.
(6) Industrial Application – Suitable for production line quality control and laboratory testing.
Accessories
(1) Wire clamping fixtures
(2) Steel rod (3 mm)
(3) Control system interface
(4) Motor drive unit
(5) Data acquisition system
(6) User manual
Test Procedures
(1) Fix the wire sample securely in the clamping fixture.
(2) Set the required force range and test speed.
(3) Adjust parameters via potentiometer or software interface.
(4) Start the test; the machine applies force to strip the insulation.
(5) Record the stripping force and observe insulation behavior.
(6) Generate and save the test report for analysis.
Maintenance Information
(1) Regularly inspect clamps and moving parts for wear.
(2) Keep the machine clean and free from dust or debris.
(3) Calibrate force measurement system periodically.
(4) Check electrical connections and control system stability.
(5) Lubricate mechanical components as required.