Toll free:400-82-13149 PHONE

Gas Fume Chamber

  • introduction

Gas Fume Chamber
Gas fume chamber is designed to test the color fastness of fabric exposed to nitrogen oxide produced by gas combustion. The tester Includes test chamber, combustion chamber, control chamber, observation door, control panel, timer, temperature control meter, air valve switch, fan and smoke exhaust device.

Test Standards
ISO 105-G02、AATCC 23, BS 1006:1990-G02, GB/T 11040
 
Test System
The  gas fume color fastness test system sets the sample in a certain concentration of smoke environment until a certain color change or  for a regulated time, and then compare the sample with the standard chart card.
This machine is suitable for testing the color fastness of all textiles except loose fibres when exposed to atmospheric nitrogen oxides produced by chemical butane gas or urban gas combustion.
Textile samples and control samples are placed in the gas smoke at the same time until the color of the control sample changes to the color of the fading standard. Use the grey sample card to assess the discoloration of the sample. If the sample is not discoloured after one test period, continue the specified test times or the required test cycles for sample to reach the specified color change.
The gas fume color fastness tester, after a certain time, observe the change process of the color of  tested fabric exposed to the nitrogen oxide produced by the combustion of gas.
The machine is composed of combustion chamber, test chamber, exhaust outlet and control panel. The combustion chamber includes the Bunsen burner, automatic ignition device, etc. The test chamber includes the rotary sample clamp, the observation light, etc. The control panel can set the test temperature, test time and the overtemperature alarm time.
During operation, the machine can automatically detect temperature of test chamber, if the test chamber temerature is below the set value, automatic ignition increas temperature rising, and then shut down automatically when reaching the set value. The flame size can be manually adjusted .

Test Principle
Textile samples and control samples are placed in the gas smoke at the same time until the color of the control sample changes to the color of the fading standard. Use grey grey card to assess the discoloration of sample.
If the sample is not discoloured after onw test period, the number of specified test times can be continued or to the required test cycles for samples to reach the specified color change.

Technical Paramters
1. Rotation speed: approximately 2R/MIN
2. Test chamber: SUS material
3. Sample size: 100mmX40mm
4, Test  temperature: 60 ℃ or less
5. Control mode: PLC control
6. Combustion gases:pure chemicalbutane gas or urban artificial gas
7. Volume: 62X70X82mm
8. Weight: 75KG
9. Power supply: AC 220V 50HZ 3A

Standard Accessories
Spring clamp x12, burning torch x1
 
Standard Consumables
Control sample card, reference sample card
 
Optional Accessories
Gey scale for color assessment