The Single Wire Cable Burning Tester is applicable to the test method and test requirements of single insulated wire or cable combustion under the prescribed flame condition.
Standards
GB/T 18380.11-2008 Vertical flame spread test of single insulated wire or cable. Test apparatus.
GB/T 18380.13-2008 The combustion test of cable and cable in flame conditions. Part 13: Vertical flame spread test of single insulated wire or cable. Test method for testing the burning dropping (drops)/particles.
Technical Parameters
1. Metal covering dimension :Width(1200±25)mm,Height(300±25)mm,Depth(450±25)mm
2. Fuel gas:Propane with purity over 95%.
3. Testing cable length:(600±25)mm